BCS-1012
A high-channel-density system for cell ageing studies and repeated battery testing.
Technical overview
- Channel capacity
- 32 / module
- Base current / channel
- ±6 A
- Voltage
- 0–5 V
- EIS frequency range
- No built-in EIS
- Software
- BT-Lab Suite
32 channels per module, ±6 A and 0–5 V. No built-in EIS is specified. The description and table disagree on the number of current ranges; confirm before ordering.

Plan the configuration
For parallel screening and ageing within the stated current and voltage limits. Consider an EIS-equipped BCS-900 configuration if cycling and impedance measurements must use the same instrument.
- Auxiliary temperature measurements
The manufacturer description gives differing numbers of current ranges; confirm this during configuration review.
Describe the cell, measurement method and number of parallel experiments. Include current and voltage requirements, EIS, low-current sensitivity and accessories when requesting a quotation.
Software
BT-Lab® Suite →Applications
Battery research and testing →Manufacturer source checked: 2026-09-15